Ultrasonic Wall Thickness Gauge | Checkline TI-44N

Measuring Range in Steel
0.040 – 8.00 inches
1.00 – 200.0 mm

The new CHECK-LINE TI-44NA Ultrasonic Wall Thickness Gauge accurately measures wall thickness and the extent of corrosion of all metals, ceramics, glass and most rigid plastics – from only one side!

The attractive, ergonomic housing design is extremely compact, lightweight and rugged. It fits comfortably in the palm of your hand and incorporates a back light that illuminates the LCD in poorly lit areas. This product is similar to our TI-45N, however the probe is hard-wired to the gauge and is NOT removable as in the TI-45N.

Features

  • NIST-Traceable Calibration Certificate & Test Report is optionally available
  • TI-44NA includes new Pipe Mode for stable measurement on small diameter pipe (1″ and larger)
  • Resolution of 0.001″ (0.01mm) with Switch-selectable units of inches or mm
  • Extremely small & lightweight operating from a single AA battery.
  • Fixed-mounted probe is connected to gauge with one meter flexible cable (39″)
  • Built-in calibration test plate on front of gauge housing
  • Quick display update with last reading retained on the display
  • Display symbols alert user to poor coupling and low battery conditions
  • Warranty – Gauge 1 year Probe 90 days
  • Made in Japan

Related Products

Click image for more info
Ultrasonic Wall Thickness Gauge
– Resolution of 0.001″ (0.01mm)
Certified Steel Test Blocks

Click image for more info
Certified Steel Test Blocks
– Includes NIST Traceable Calibration Certificate
– Precision Machined and Finished
– Includes Storage Box
SB4 & SB6 Uncertified Steel Test Blocks

Click image for more info
Ultrasonic Test Blocks without certification
– Fabricated from 1018 Steel or 304 Stainless Steel
– ISO Calibration OPTIONAL
CF12 Sound Safe Ultrasonic Couplant

Click image for more info
Coupling Fluid
– Temp Range: 0 – 200 °F, -18 – 93 °C

Complete Kit

The TI-44NA is supplied as a complete kit with the gauge and wrist strap, probe and cable assembly, 2 oz. bottle of coupling fluid, battery and instruction manual — all supplied in a cardboard pack as shown.

Measuring Limits

Minimum Radius for Convex Surfaces 1″ (25.4 mm)
Minimum Radius for Concave Surfaces 3″ (76.2 mm)
Minimum Headroom 3″ (76.2 mm)
Minimum Sample Diameter 0.5″ (12.7 mm)
Minimum Substrate Thickness – F na
Minimum Substrate Thickness – NFe na

Specifications

Range in Steel 0.040 – 8.000″ (1.0 – 200.0 mm)
Resolution .001″ (0.01 mm)
Display 4½ – digit LCD display, 0.39″ (10mm) high with push button illumination
Velocity Range 3,250 – 39,000 ft/sec
(1,000 – 12,000 m/sec)
continuously adjustable
Probe 5 MHz, .39″ (10 mm) diameter
Cable 39″ (1m) 2-wire, long cable with fixed-mounted to gauge body
Minimum Pipe Size 1″ nominal (30mm) steel pipe
Temp. Limits Ambient: 25 to 125° F (-5 to 50° C)
Material: -15 to 140° F (-10 to 60° C)
Calibration Plate 0.250″ (6.35mm) steel plate, built into the front of the housing
Battery Type 1x AA battery
Battery Life 200 hours
Weight Gauge: 7 ounces (200 g)
Size 5.2″ x 2.7″ x 1.1″
(131 x 68 x 29 mm)
Warranty Gauge: 1 years
Probe: 90 days
Accessories Included 2 Ounce bottle of couplant

Reviews

There are no reviews yet.

Be the first to review “Ultrasonic Wall Thickness Gauge | Checkline TI-44N”

Your email address will not be published.

Shopping Cart